Low voltage Phase and Feeder identifier Ariadna ILF6

    This equipment has been designed to identify on live networks the link between Low Voltage (LV) customers and MV/LV transformer, feeder and phase.

    A large problem for utilities is the lack of good customer connectivity data, and this information is of key importance for managing distribution networks effectively. On smart grids it is imperative to have an up-to-date electric model reflected on GIS, nevertheless any hope of achieving automation and reducing outage duration will be lost.

    Once loaded on GIS, more precise electric grid calculations can be made to improve quality of supply: transformer phase and feeder load balance, voltage drop between transformer and subscriber, preventive maintenance task planning, etc.

    In order to cope with this need Ariadna ILF6 identifies the link between LV customers and MV/LV transformer-feeder-phase in a fast, easy and reliable way.

    Ariadna ILF6 includes a Phase Identifier and a Feeder identifier on a single tool, and is the only equipment on the market that has this functionality.

    The equipment also works as a trouble shooting tool when installing PLC communicated smart meters. It lets the user know the path PLC signals must follow to properly communicate data.

Low voltage Phase and Feeder identifier Ariadna ILF6's Central Unit.Central Unit ILF6 CU
     Works without de-energizing the line, so electrical supply is kept throughout the identification process.

     Central Unit (UC) is connected to transformer LV side, and injects phase and feeder codes throughout the LV network.
Low voltage Phase and Feeder identifier Ariadna ILF6's Line Unit.Line Unit ILF6 LU
   Line Unit (LU) is connected to the LV customer side, and after a few seconds shows subscriber’s connectivity information (phase and feeder) on a LCD display.

    “Plug and Play”. Contains what is needed to start working, without any additional adjustment or programming.

Ariadna ILF6 Low Voltage phase and feeder identifier’s working example.
    On this video a practical example of Ariadna ILF6 Low Voltage phase and feeder identifier can be seen.
Working with the Low voltage Phase and Feeder identifier Ariadna ILF6.
FEATURES:
« Works on live networks, without de-energizing the line »
« Three phases and up to 6 feeders can be identified in a few seconds »
« Proved efficiency in lines of more than 1 km »
« Central and Line Unit communicate with each other by means of coded messages through the distribution network. This way the use of radio or other communication extra equipment is avoided »
« Usable by a single operator »
« Operational for all kinds of Low Voltage network configurations, up to
480 V between phases, 50 or 60 Hz, with coupled and/or ringed lines »
« “Plug and Play”. Contains what is needed to start working, without any additional adjustment or programming »
Click here to download more information on Ariadna ILF6 Low Voltage phase and feeder identifier
 